Separator, filter, and compressor systems are critical components in marine and industrial operations, ensuring the seamless performance of engines, water treatment, fuel purification, and compressed air supply. To maintain optimal performance and extend the service life of these systems, it is essential to identify common faults early and apply the right maintenance solutions. In this comprehensive guide, we will cover typical problems, their causes, and practical solutions, categorized by system type. All examples and suggestions align with Maridec Marine’s spare part expertise and inventory, ensuring accuracy and applicability.
Separator Systems – Common Issues and Fixes
1. Low Separation Efficiency
Possible Cause: Bowl contamination, worn disc stack, improper sludge removal.
Solution: Clean the bowl thoroughly, inspect and replace disc stacks if needed. Check auto-sludge discharge system operation.
2. Excessive Vibration
Possible Cause: Misalignment, worn bearings, unbalanced bowl.
Solution: Replace bearing kits (use original Major Kit if needed), realign motor shaft and bowl, ensure proper balancing during reassembly.
3. Oil Leakage
Possible Cause: Damaged mechanical seal or O-rings.
Solution: Replace seals and O-rings using Minor Kit or individual parts. Always use manufacturer-approved components.
4. Overheating Motor
Possible Cause: Blocked oil line, faulty cooling fan.
Solution: Clean oil line, inspect fan for damage, and replace via spare parts list (Friction Coupling, Fan Assembly).
Filter Systems – Common Issues and Fixes
1. Reduced Flow Rate
Possible Cause: Clogged filter elements or bypass valve stuck.
Solution: Replace clogged cartridges with genuine filter elements (e.g., Boll&Kirch, Moatti). Clean bypass valve housing.
2. High Differential Pressure
Possible Cause: Dirty or degraded filter media.
Solution: Monitor pressure gauges, replace filters regularly as per operating hours. Use Candle Filters or Ultra Fine Filters for extended cycles.
3. Filter Bypass Activation
Possible Cause: Faulty spring or valve seat.
Solution: Replace damaged spring (Spring Pin, Spring Set) and valve body from Maridec Marine stock.
4. Leakage at Flange Connection
Possible Cause: Improper gasket sealing.
Solution: Use new gaskets from the correct kit (Seal Ring, O-Ring Kit), ensure proper torque during reassembly.

Compressor Systems – Common Issues and Fixes
1. Pressure Drop
Possible Cause: Valve failure, worn-out piston rings.
Solution: Replace valves, rings, and seals from recommended Intermediate or Major Kits. Brands supported: Hatlapa, Sauer, Sperre.
2. Oil Carryover
Possible Cause: Damaged separator element.
Solution: Replace separator cartridge and check crankcase ventilation. Compatible with MICFIL, Atlas Copco components.
3. Frequent Tripping
Possible Cause: Electrical overload or thermal cut-out due to insufficient lubrication.
Solution: Inspect oil level, clean filters, replace overload relay or thermal sensor. Use EPC50 diagnostics module.
4. Abnormal Noise
Possible Cause: Bearing wear or loose coupling.
Solution: Replace bearings (Axial Bearing, Ball Race), realign shafts, and inspect Coupling Kits.
General Maintenance Recommendations
- Use original Alfa Laval, GEA, Mitsubishi, and Westfalia kits for separator maintenance.
For filters, ensure compatibility with Boll Filter, Sondex, and SPX Flow systems.
Compressors should be serviced using brand-specific overhaul kits (Hatlapa, Tanabe, etc.).
Avoid using counterfeit or non-OEM parts to maintain certification and system warranty.
Schedule preventive maintenance every 3,000-5,000 operational hours depending on the system.
Quick Reference Table – Troubleshooting Summary
Issue | Likely Cause | Solution |
---|---|---|
Poor distillation output | Fouled condenser or ejector nozzle | Clean/replace affected parts |
Overheating of engine coolant | Scale buildup in heat exchanger plates | Descale and replace rubber gaskets |
Water leakage | Cracked plate or worn gasket | Replace damaged components |
Excessive backpressure in filter | Clogged filter elements | Clean or replace filter cartridges |
False salinity readings | Malfunctioning salinometer sensor | Calibrate or replace sensor |
Maridec Marine’s Expertise
At Maridec Marine, we specialize in providing high-quality, OEM-certified spare parts for separator, filter, and compressor systems. Our inventory includes thousands of items such as EPC50 modules, actuator kits, intermediate kits, and O-ring sets, ensuring full compatibility with top marine brands.
From positive displacement screw pumps to ultra-fine filtration elements, we deliver tailored solutions to improve efficiency and reduce your vessel’s carbon footprint. Whether it’s Alfa Laval separator kits, MICFIL filters, or GEA maintenance assemblies, we’ve got your needs covered.
Need Technical Support or Parts Quotation?
Contact Maridec Marine’s technical team today for tailored spare parts solutions and maintenance consultancy.
👉 Fill out the request form on our website and we’ll get back to you within 24 hours.